Remote Monitor VisuNet EX1 RM519

VisuNet EX1 RM519
  • Remote Monitor
  • Can also be operated as Extended Desktop, Clone Monitor and with several host PCs
  • Device installation in Zone 1 and Zone 21
  • 19 inch monitor (48.3 cm)
  • Network based data transfer via Ethernet (optional RDP, or VNC)
  • Adapted for distances up to 90 m (or 2 km by using an optionbox)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  VisuNet EX1 RM519

General specifications
TypeRemote Monitor
Supply
Rated voltage24 V DC ( 20 ... 30 V DC )
Power consumptionmax. 75 W
Indicators/operating means
Display
TypeTFT, LCD
Screen diagonal48.3 cm (19 inch)
Resolution1280 x 1024 pixels
representable: 640 x 480 up to 1280 x 1024 pixels
Color depth16 Mio.
Contrast1000:1
Brightness300 cd/m2 (nit)
Reading angle89° / 89° / 89° / 89°
Life span50.000 h @ 25 °C
Input devicesAnalog resistive touch screen (optional) ,
Keyboard with integrated mouse functionality: touch pad/joystick versions available
Interface
Interface typeUSB , RS-485, RS-422, RS 232, Ethernet , TTY
Ambient conditions
Operating temperature-10 ... 50 °C (14 ... 122 °F) (at switching on)
-20 ... 50 °C (-4 ... 122 °F) (when operating)
Storage temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humiditymax. 85 % non-condensing (48 h endurance test)
Mechanical specifications
Degree of protectionIP66
InstallationMountable on floor, wall or ceiling
several mounting options (turnable/fix) available
Massapprox. 41 kg
Dimensions537 x 457 x 158 mm (display)
590 x 700 x 470 mm (surface-mounted case)
Cut out dimensions466 mm x 389 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 07 ATEX E 008 X 2nd Edition
MarkingEx-Hexagon II 2 G Ex e mb q [ib] IIC T4 Gb
Ex-Hexagon II 2 D Ex tb [ib] IIIC T85°C Db
Ex-Hexagon II 3 (2) G Ex e mc q [ib Gb] IIC T4 Gc
Ex-Hexagon II 3 (2) D Ex tc [ib Db] IIIC T85°C Dc
International approvals
IECEx approvalIECEx BVS 08.0030X

Classifications

SystemClasscode
ECLASS 13.027330201
ECLASS 12.027330201
ECLASS 11.027330201
ECLASS 10.0.127330201
ECLASS 9.027330201
ECLASS 8.027339090
ECLASS 5.127242402
ETIM 9.0EC001428
ETIM 8.0EC001428
ETIM 7.0EC001428
ETIM 6.0EC001428
ETIM 5.0EC001428
UNSPSC 12.139121106

Details: VisuNet EX1 RM519

Product Documentation: VisuNet EX1 RM519

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction leaflet / BeipackzettelALLPDF281 KB
Safety and Security Documentation
Instruction Manual VisuNet EX1 RM5*/PC4*ENGPDF991 KB
Manuals
Hardware Manual VisuNet Ex1 RM and PCENGPDF2995 KB