Datasheet excerpt: Technical data of  5500-MAN-EX01-*

General specifications
Operating modeautomatic purging
Series5500
SystemType Z Purge ; Ex pzc Purge
Hazardous environmentgas or dust
Supply
Rated power24 VDC: 2.6 W
120 VAC: 50...60 Hz, 0.029 A
230 VAC: 50...60 Hz, 0.014 A
(Voltage tolerance: +/-10%)
Electrical specifications
Fuse ratingDC: 500 mA
AC: 80 mA
(fuse rating on 5500 control unit)
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirement1.7 bar (25 psi) to 8.0 bar (115 psi)
Purge flow ratesolenoid valves : Cv (flow coefficient) = 1.4
needle valve : Cv (flow coefficient) = 0.25
Ambient conditions
Ambient temperature-20 ... 50 °C (-4 ... 122 °F) T5
Mechanical specifications
Connection typePneumatic
Input port: 3/8 inch Tube compression fitting
Output port: 3/8" Tube compression fitting

Degree of protectiontype 7 & 9
Material
Housing: anodized aluminum
3/8" compression fittings: 316 stainless steel
Pressure ports: 3/8" NPTF
Bulkhead fitting: 316 stainless steel
Mounting bolts: 1/4 - 20, 316 stainless steel
Sealing washers: UL recognized type 4X
Cable3 m
Mass1250 g (2.8 lb)
Dimensionssee dimensions
Data for application in connection with hazardous areas
EU-type examination certificate
MarkingEx-Hexagon II 2 G Ex mb IIC T5 Gb
Ex-Hexagon II 2 D Ex mb tb IIIC T95C Db IP65
Protection by encapsulation

PTB 03 ATEX 2018 X
International approvals
IECEx approvalEx-Hexagon II 2 G Ex mb IIC T5 Gb
Ex-Hexagon II 2 D Ex mb tb IIIC T95C Db IP65
Protection by encapsulation
IECEx PTB 04.0002X

Classifications

SystemClasscode
ECLASS 13.027180591
ECLASS 12.027180591
ECLASS 11.027180591
ECLASS 10.0.127291390
ECLASS 9.027291390
ECLASS 8.027291390
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121303

Details: 5500-MAN-EX01-*

The 5500-MAN-EX01-* combines a solenoid valve for purging and a needle valve for pressurization in one manifold design. When the valve is energized, the solenoid valve is open and allows for a high flow rate of protective gas into the enclosure. When the valve is deenergized, the flow through the internal needle valve is adjustable by a flathead screw driver through the needle stem on the manifold. The solenoid valve is used for purging, leakage compensation, and temperature control by signals from user defined points on the 5500 control unit.

Mounting hardware includes 3/8" tube compression fittings mounted on the manifold for input and output flow, 3/8" tube compression bulkhead fitting for getting flow into the enclosure and certified sealing washers with bolts to mount the manifold to the enclosure. Also included is 1 meter of 3/8" poly tubing with 3/8" poly tube stiffener inserts which allows the connection of plastic tubing to compression fittings without collapsing the tubing.

The 5500-MAN-EX-01-* is certified for Zone applications. For NEC, Class/ Division applications see the model number key for proper manifold selection.

The 5500 valve system works with the 5500 control unit and EPV-5500 vents.

The 5500 system has ATEX and IECEx certification for Zone 2&22 installation.

Datasheet: 5500-MAN-EX01-*

DatasheetFile TypeFile Size
Datasheet 5500-MAN-EX01-*PDF596 KB
Datenblatt 5500-MAN-EX01-*PDF611 KB

Documents: 5500-MAN-EX01-*

Instruction manualsFile TypeFile Size
ИнструкцииPDF168 KB
Instruction manual / BetriebsanleitungPDF338 KB
Návod k poużitíPDF163 KB
Instruktions manualPDF162 KB
Instruction manualPDF164 KB
KasutusjuhendPDF157 KB
KäyttöohjePDF157 KB
Manuel d'instructionsPDF165 KB
BetriebsanleitungPDF169 KB
Οδηγίες χρήσηςPDF172 KB
HandleidingPDF164 KB
Instruction manual / BetriebsanleitungPDF162 KB
Használati útmutatóPDF164 KB
Manuale di istruzioniPDF163 KB
Lietošanas pamācībaPDF161 KB
Instrukciju vadovasPDF163 KB
Instrukcja obsługiPDF166 KB
Manual de instruçõesPDF165 KB
Manual de utilizarePDF163 KB
Návod na poużitiePDF163 KB
Navodila za uporaboPDF161 KB
Manual de instruccionesPDF164 KB
ManualPDF161 KB

CAD+CAE: 5500-MAN-EX01-*

CADFile TypeFile Size
DWG and STP files for the Purge 5500-MAN-EX01 / CAD 2-DZIP326 KB

Associated Products: 5500-MAN-EX01-*

Accessory of
1,433.12  USD

Contact Us

You must purchase an EPV-7500-* vent with this control unit.pa
1,329.12  USD

Contact Us

You must purchase an EPV-7500-* vent with this control unit.pa
1,329.12  USD

Contact Us

You must purchase an EPV-7500-* vent with this control unit.pa
1,433.12  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

You must purchase an EPV-7500-* vent with this control unit.pa

Get to know the smartest way to ensure hazardous location protection and configure your individual purge and pressurization system!

Our interactive app gives you a step-by-step programming simulation for your purge and pressurization system. Download the free-of-charge app for iOS or Android devices now …

Ex p Purge Units

Discover the all-new 5500 Series. These compact purging units enable fully automatic protection.