Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

AS-Interface splitter box VAZ-2T8-G11-V1

VAZ-2T8-G11-V1
  • Less space required
  • Field housing with degree of protection IP67
  • Simple and fast mounting
  • Distribution to 8 V1 connectors (M12)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  VAZ-2T8-G11-V1

Product Description
Splitter box, M12, AS interface and auxiliary voltage to eight M12 connectors
Indicators/operating means
LED AS-iAS-Interface voltage; dual LED green/red
green: voltage OK
red: reversed voltage
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
Electrical specifications
Rated operating voltage≤ 32 V PELV ( AS-Interface , ext. auxiliary voltage AUX )
Rated operating current≤ 4 A
Protection classIII
Surge protectionovervoltage category III
Pulse withstand voltage800 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Standard conformity
Degree of protectionEN 60529:2000
AS-InterfaceEN 62026-2:2013
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree3
Mechanical specifications
Degree of protectionIP67 according to EN 60529
ConnectionPlug connection: M12 x 1 socket (V1) Connector: 1 x M12 connector (V1)
Material
ContactsCuSn / Au
HousingPBT PC
Mounting screwStainless steel 1.4305 / AISI 303
Mass120 g
Tightening torque, housing screws1.8 Nm
Tightening torque, cable gland0.4 Nm
Dimensions
Height35 mm
Diameter85 mm
MountingMounting plate

Classifications

SystemClasscode
ECLASS 13.027440111
ECLASS 12.027440111
ECLASS 11.027440111
ECLASS 10.0.127440111
ECLASS 9.027440108
ECLASS 8.027279219
ECLASS 5.127279201
ETIM 9.0EC003558
ETIM 8.0EC003558
ETIM 7.0EC003558
ETIM 6.0EC002585
ETIM 5.0EC002585
UNSPSC 12.131261501

Details: VAZ-2T8-G11-V1

Function

The VAZ-2T8-G11-* splitter box is used to distribute the AS-Interface connection and the external auxiliary power to eight M12 x 1 quick disconnects. Due to its passivity the distributor does not require an own address on the AS-Interface-net. It is ideal for applications in the field owing to the protection class IP67. LEDs indicate correct polarity of the AS-Interface cable or the external auxiliary power.

Informative Literature: VAZ-2T8-G11-V1

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Automating Material Handling Systems for Airports with AS-InterfaceENGPDF272 KB

Product Documentation: VAZ-2T8-G11-V1

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction leaflet / BeipackzettelALLPDF774 KB

Design / Simulation: VAZ-2T8-G11-V1

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP4756 KB
CAD Portal / CAD PortalALLLINK---

Approvals: VAZ-2T8-G11-V1

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
EU Ecolab Material ResistanceECOLABALLPDF1797 KB
Declaration of Conformity