Fieldbus Terminator, Field Mounting (Ex d) F*-FT-Ex1.D.IEC

F*-FT-Ex1.D.IEC
  • Terminator in stainless steel housing
  • Flameproof enclosure (Ex d) protection
  • Installation on open cable gland
  • Choice of threads 20 mm, Pg 13.5 mm or 1/2" NPT
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  F*-FT-Ex1.D.IEC

General specifications
Design / MountingOutside installation
Fieldbus connection
Connection2-wire cable, red+, black-
Rated voltagemax. 32 V DC
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Standard conformity
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC/EN 60529
Fieldbus standardIEC 61158-2
Ambient conditions
Ambient temperature-50 ... 85 °C (-58 ... 185 °F)
Storage temperature-50 ... 85 °C (-58 ... 185 °F)
Mechanical specifications
Core cross section0.75 mm2
Housing77 mm x 22 mm
Degree of protectionIP67
Mass100 g
Mounting20 mm ISO thread
PG13.5 thread
1/2 NPT thread
Data for application in connection with hazardous areas
EU-type examination certificateDMT 01 ATEX 104 X
MarkingEx-Hexagon II 2G EEx d IIC T6
Temperature classT6 for ambient temperature ≤ 60 °C
T5 for ambient temperature ≤ 75 °C
T4 for ambient temperature ≤ 85 °C
Maximum values
Rated voltage< 253 V AC / 125 V DC
Operating values
Rated voltagemax. 32 V
Directive conformity
Directive 94/9/ECEN 60079-0:2006 , EN 60079-1:2007 , EN 60079-26:2007
International approvals
IECEx approvalIECEx BVS 10.0022X
Approved forEx d IIC T6 Gb
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242692
ECLASS 12.019170104
ECLASS 11.027242692
ECLASS 10.0.127242692
ECLASS 9.027242692
ECLASS 8.027242692
ECLASS 5.127242692
ETIM 9.0EC002584
ETIM 8.0EC002584
ETIM 7.0EC002584
ETIM 6.0EC002584
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: F*-FT-Ex1.D.IEC

Function

F*-FT-Ex1.D.IEC are terminators for fieldbus and provide capacitance and resistance to terminate a segment according to IEC/EN 61158-2. Explosion protection is flameproof enclosure 'Ex d' for installation in Zone 1 … 2. A solid metal housing enables installation in rough environments. Housings are selectable with 20 mm ISO, 13.5 mm PG, or 0.5 in NPT threads for easy installation on outdoor fieldbus junction boxes or field devices.

For increased availability, the terminator features multiple capacitors and resistors in a network. If one capacitor fails, the basic functionality remains intact. This is detectable with the FieldConnex ® advanced diagnostic module, allowing timely maintenance.

Terminators are required at each end of the trunk line. They eliminate signal reflections at the end of the cable and convert the fieldbus signal transmitted as a current into a voltage, which is detectable by all devices.

Informative Literature: F*-FT-Ex1.D.IEC

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronENGPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingENGPDF470 KB

Product Documentation: F*-FT-Ex1.D.IEC

Language Selection:
Safety and Security DocumentationLanguageFile TypeFile Size
Instruction Manual F*-FT -Ex1.I.IEC, F*-FT-Ex1.D.IECENGPDF1794 KB

Approvals: F*-FT-Ex1.D.IEC

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
BVS IECEx Certificate of ConformityIECEx BVS 10.0022XALLLINK---
Canada, USA CSACoC 1284467ALLPDF73 KB
Control Drawings
Control drawing CSA / Control drawing CSA   ALLPDF104 KB

Associated Products: F*-FT-Ex1.D.IEC

Accessory of
Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk
Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 1 - intrinsically safe trunkpa

Ethernet-APL enables continuous communication across all hierarchy levels. Learn more about the pioneering technology …

RSS Info Service for PANOS Updates

Stay informed when a new software update of PANOS, the operating system for Ethernet-APL switches, is released: With our RSS Feed you will get an email notfication in your inbox immediately after an update has been released.

From decisions to planning, installation, and commissioning up to operation and maintenance: Discover how to make the most out of your fieldbus infrastructure …