Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

AS-Interface sensor/actuator module VAA-4E4A-KE-ZE/R

  • Housing with removable, mechanical and color coded terminals
  • Communication monitoring
  • Inputs for 2- and 3-wire sensors
  • Isolated relay output
  • Addressing jack
  • Selectable supply to the sensors: External or from the module
  • Function display for bus, internal sensor supply, inputs, and outputs
Unit Price:  235.00 USD
 in stock

Download the complete datasheet as a PDF:

Datasheet excerpt: Technical data of VAA-4E4A-KE-ZE/R

Product Description
KE switch cabinet module
4 inputs (PNP) and 4 relay outputs
General specifications
Slave typeStandard slave
AS-Interface specificationV2.1
Required master specification≥ V2.0
UL File NumberE106378
Functional safety related parameters
MTTFd300 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED FAULTFault display; Red LED
red: Communication fault or address is 0
red, flashing: Overload, internal input supply
LED INTInternal input supply active; LED green
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 4 LED yellow
LED OUTSwitching state (output); 4 LED yellow
Electrical specifications
Auxiliary voltage (input)12 ... 30 V DC PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 35 mA (no sensors)/max. 210 mA
Surge protectionO1 ... O4: Over voltage category II
UEXT, Ue: Over voltage category III, safe isolated power supplies (PELV)
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface (switch position INT, basic setting) or external UEXT (switch position EXT)
Voltage21 ... 31 V DC (INT)
Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT)
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 2 mA
1 (attenuated)≥ 4 mA
Signal delay< 2 ms (input/AS-Interface)
Number/Type4 relay outputs, normally open
Nominal load
Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC
Per module8 A
Control circuit≤ 8 mA per relay (from AS-Interface)
Switching delay< 10 ms (AS-Interface/contact)
Usage categoryDC-13 and AC-14
Mechanical5 x 106
Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4)
Electrical isolation
Input/Outputsafe isolation, rated insulation voltage 300 V AC
Input/AS-InterfaceSwitch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC
Output/Outputbasic insulation, rated insulation voltage 300 V AC
Output/AS-Interfacesafe isolation, rated insulation voltage 300 V AC
Programming instructions
IO code7
ID code0
ID1 codeF
ID2 codeE
Data bits (function via AS-Interface) input output
D0 IN1 O1
D1 IN2 O2
D2 IN3 O3
D3 IN4 O4
Parameter bits (programmable via AS-i)function
P0not used
P1not used
P2not used
P3not used
Compliance with standards and directives
Directive conformity
Low Voltage Directive 73/23/EECEN 60947-1:2007
EMC Directive 2004/108/ECEN 61326:2003
Standard conformity
Electromagnetic compatibilityNAMUR NE 21: 1998-08
Electrical isolationEN 60947-1
Degree of protectionEN 60529:2000
Fieldbus standardEN 50295:1999
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution Degree2
Mechanical specifications
Degree of protectionIP20
Connectionremovable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-section:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
HousingPA 66-FR
Mass170 g
MountingDIN mounting rail
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm

Documents: VAA-4E4A-KE-ZE/R

Instruction leafletsLanguageFile TypeFile Size
Beipackzettel/Instruction leafletALLPDF556 KB


CADFile TypeFile Size
3-D-Modell/3-D modelIGS138 KB
3-D-Modell/3-D modelSTP112 KB

Approvals+Certificates: VAA-4E4A-KE-ZE/R

Statements of complianceCertificate No.File TypeFile Size
EU-Konformitätserklärung/EU-Declaration of conformityDOC-1010PDF96 KB
Canada UL cULE106378 cUL (QUZW7)LINK---
Worldwide AS-International Association AS-Interface48501PDF578 KB
Russia TUV GOST-R101-KC/542PDF90 KB
Europe Pepperl+Fuchs 2004/108/EC - 2006/95/EC Declaration of ConformityPF 08 CERT 1280PDF360 KB

Associated Products: VAA-4E4A-KE-ZE/R

VBP-HH1-V3.0-KITAS-Interface Handheld with accessory
VAZ-PK-1,5M-V1-GAdapter cable module/hand-held programming device

AS-Interface Switch Cabinet Module KE5 – Simple Handling and Improved Manageability

The unique housing design of the new KE5 switch cabinet module enables distinct visibility and simplifies mounting, wiring, and maintenance inside switch cabinets and junction boxes.