Inductive analog sensor ANT2-8 2084/85 V1

ANT2-8 2084/85 V1
  • Inductive analog
  • Output 0 V ... 10 V
  • Output 0 mA ... 20 mA
  • Non-flush mountable

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  ANT2-8 2084/85 V1

General specifications
Output typeAnalog current output or analog voltage output
Installationnon-flush
Output polarityDC
Measurement range2 ... 8 mm
Output type3-wire
Nominal ratings
Operating voltage18 ... 30 V
Output signal0 ... 20 mA 0 ... 10 V
Reverse polarity protectionreverse polarity protected
Linearity error± 0.5 %
Temperature drift≤ 0.2 % / K v.E.
Repeat accuracy< 0.02 mm
No-load supply current≤ 15 mA
Load resistorvoltage output: ≥ 4,7 kΩ
current output: ≤ 200 Ω
Electrical specifications
Linearity± 5 % v.E.
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeM12 x 1
Housing materialbrass, nickel-plated
Sensing facePBT
Degree of protectionIP67
Dimensions
Length70 mm
Diameter18 mm

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: ANT2-8 2084/85 V1

Approvals: ANT2-8 2084/85 V1

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
China Information on CCCCCC-Exempt Declaration (Pepperl+Fuchs)ALLPDF457 KB

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.