Serviceline Industrial Sensors
Serviceline Explosion Protection

Fieldbus Power Hub, Gateway Motherboard MB-FB-GTR1*

MB-FB-GTR1*
  • For 2 gateway modules
  • For PROFIBUS PA
  • Redundant configuration
  • Installation in Zone 2/Class I, Div. 2
  • Spring terminals or screw terminals selectable

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  MB-FB-GTR1*

General specifications
Design / MountingMotherboard based
Supply
Rated voltage19.2 ... 35 V SELV/PELV
Rated current2 ... 3 A
Indicators/operating means
Fault signalVFC alarm output via connectors
Rotary switchbus addressing, gateway-specific
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Housing materialPolycarbonate
Degree of protectionIP20
Massapprox. 300 g
MountingDIN mounting rail
Data for application in connection with hazardous areas
CertificateTÜV 15 ATEX 7735 X
MarkingEx-Hexagon II 3 G Ex ec IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018
International approvals
IECEx approvalIECEx TUR 16.0007X
Approved forEx ec IIC T4 Gc
Certificates and approvals
Marine approvalpending
General information
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242603
ECLASS 12.027242603
ECLASS 11.027242603
ECLASS 10.0.127242603
ECLASS 9.027242603
ECLASS 8.027242603
ECLASS 5.127242603
ETIM 9.0EC001598
ETIM 8.0EC001598
ETIM 7.0EC001598
ETIM 6.0EC001598
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: MB-FB-GTR1*

This motherboard is a system component of the FieldConnex ® Power Hub. It is the mounting base and wiring interface for 2 communication gateways. In connection with power supply modules and the respective motherboard it forms a complete unit for power supply of segments with data conversion.

Sockets for all modules enable simple installation and replacement without tools. Wire connections can be selected as spring terminals or screw terminals.

The motherboard supports a choice of gateways for different host protocols. A PROFIBUS PA master for each segment enables short bus cycle times. The DCS can access the advanced diagnostic module directly via the gateway without additional wiring or configuration.

Datasheet: MB-FB-GTR1*

DatasheetFile TypeFile Size
Datasheet MB-FB-GTR1*PDF875 KB
Datenblatt MB-FB-GTR1*PDF870 KB

Documents: MB-FB-GTR1*

ManualsFile TypeFile Size
Manual für use with HCD2-FB*, MBHC-FB-4.HSC*, MBHC-FB-4R.HSC*, MB-FB-GTR1, MBHC-FB-4.GTPDF3939 KB
PROFINET Manual for use with HD2-FB*, MB-FB*.GEN, MBHD-FB*.GEN, MBHD-FB-D-4R.GEN, MB-FB-GT, MB-FB-GTRPDF4416 KB
Instruction manuals
ИнструкцииPDF166 KB
Instruction manual / BetriebsanleitungPDF320 KB
Návod k poużitíPDF160 KB
Instruktions manualPDF160 KB
Instruction manualPDF166 KB
KasutusjuhendPDF157 KB
KäyttöohjePDF156 KB
Manuel d'instructionsPDF162 KB
BetriebsanleitungPDF167 KB
Οδηγίες χρήσηςPDF169 KB
HandleidingPDF160 KB
Instruction manual / BetriebsanleitungPDF160 KB
Használati útmutatóPDF161 KB
Manuale di istruzioniPDF160 KB
Lietošanas pamācībaPDF159 KB
Instrukciju vadovasPDF161 KB
Instrukcja obsługiPDF163 KB
Manual de instruçõesPDF161 KB
Manual de utilizarePDF160 KB
Návod na poużitiePDF160 KB
Navodila za uporaboPDF158 KB
Manual de instruccionesPDF161 KB
ManualPDF159 KB
Application reports
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingPDF470 KB
Application Report - Fieldbus Power Supply Compatible with Process Industry ApplicationsPDF229 KB
Applikationsbericht - Digitale Kommunikation in der Produktion von GrobblechenPDF473 KB
Applikationsbericht - Kompatible Feldbus-Stromversorgung für die ProzessindustriePDF231 KB
Applikationsbericht - Steuerung und Überwachung der Kälteanlagen im Deutschen Elektronen-SynchrotronPDF643 KB

Approvals+Certificates: MB-FB-GTR1*

CertificatesFile TypeFile Size
Europe TUV Rheinland ATEX Category 3PDF185 KB
TUV Rheinland IECEx Certificate of Conformity Zone 2LINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1040 KB

Associated Products: MB-FB-GTR1*

Matching System Components
4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
Matching System Components

PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa

Ethernet-APL enables continuous communication across all hierarchy levels. Learn more about the pioneering technology …

RSS Info Service for PANOS Updates

Stay informed when a new software update of PANOS, the operating system for Ethernet-APL switches, is released: With our RSS Feed you will get an email notfication in your inbox immediately after an update has been released.

From decisions to planning, installation, and commissioning up to operation and maintenance: Discover how to make the most out of your fieldbus infrastructure …